Posted: Mar. 20 2005,18:01 |
|
Did you do that:
Quote | Move the chassis around so that you are facing the front with the fan on your left. Locate the on/off switch on the front panel. The switch should have a white plastic barrel covering its shaft. The switch itself is mounted on the motherboard. Just to the right of the switch are a pair of jumper blocks. The jumper block closest to the front of the chassis is labeled PASSWORD OVR. Move the jumper to the left one pin so that it covers the leftmost pair of pins and the far right pin is exposed. Start the unit. Count to twenty (20), and turn the system off. Move the jumper back to its original position covering the rightmost pair of pins and exposing the leftmost pin. Wait at least 20 seconds PUT THE CF-Card into the slot and restart the system.
|
?
If yes, then you see first the blue screen with "Testing in progress" WAIT then there are appearing different screens WAIT until you see a screen with POST STARTUP ERROR(S)
go to CONTINUE Then you get a screen with ERROR go to AUTOMATICALLY RECONFIGURE SYSTEM AND CONTINUE
Next screen -> CONFIGURITION ERROR go to CONTINUE
next screen -> CONFIGURATION/SETUP UTILITY here you choose Start Options -> Setup Sequence ->Primary Startup Sequence and choose harddisk0
then 2X ESC goto SAVE SETTINGS ENTER
and the Netvista 2800 will boot again from CF-card. When You connect a harddisk to the connector, you must put a power cable from somewhere (a second power supply unit ) to the harddisk.
|